Kal Equipment 3000 Multimeter Manual

Buy KAL EQUIP 3000 DIAGNOSTICS MULTIMETER. Motorcycle in Pompano Beach, Florida, US, for US $79.99. Visually inspect the resistor and calculate its resistance and use the upper tolerance limit. Set your voltmeter/multimeter to an ohm range higher than your upper limit resistance (i.e. If your upper limit is 1,500 ohms, then your setting should be at 2,000 ohms) and then connect your test leads on the legs of the resistor. Kal Equipment 3000 Multimeter Manual 4,2/5 8290 reviews. Digital Multimeter Calibration Purpose The purpose of this procedure is to provide instruction for the calibration of digital multimeters (DMM). Scope All multimeters (multi-range instruments used to measure voltage, current, and resistance) are to be verified in calibration no less than.

Blood Pressure Simulators
Defibrillator and Pacemaker Analyzer
ECG and Universal Patient Simulators
ManualESU Analyzer
Incubator Analyzer
Infusion Pump Analyzer
Oscilloscopes
Pulse Oximeter Tester
Safety Tester and Power Analyzer
Thermometer, Thermometer Tester and Data Logger
Water Conductivity Tester
Various Biomedical
Various Electronics

CDC SmartArm

User manual
950 KB Download

Metron QA-1290

Service and user manual
1.3 MB Download

Pronk SimCube

Service manual
1.1 MB Download
Multimeter

Pronk SimCube

User manual
500 KB Download

Bio-Tek QED-6

Circuit diagram
1.4 MB Download

BC Biomedical DA-2006

Service manual
2.1 MB Download

DaleTech Dale 400

User manual
1.2 MB Download

DNI Impulse 3000

User manual
3.3 MB Download

Fluke Impulse 6000

User manual
1.9 MB Download

Fluke QED-6

User manual
1.8 MB Download

Metron QA-40,45

User manual
650 KB Download

Metron QA-45

User and service manual
430 KB Download

Bapco PS-97

User manual
3.4 MB Download

Dynatech DS-6100

User manual
2.0 MB Download

Fluke PS-420

User manual
350 KB Download

Metron (Fluke) PS-416

Pin layout for connection cable
25 KB Download

Metron (Fluke) PS-420,440

Pin layouts for different connection cables
550 KB Download

SRI Biotester

User manual
1.0 MB Download

BC Biomedical ESU-2000A

User manual
250 KB Download

Bio-Tek RF-301 B

User manual
930 KB Download

Bio-Tek RF-302

User manual (1)
660 KB Download

Bio-Tek RF-302

User manual (2)
430 KB Download

Bio-Tek RF-302

Technical description
1.2 MB Download

Bio-Tek RF-302

Specifications
80 KB Download

DNI Nevada 402A

User manual
4.5 MB Download

Fluke QA-ES II

User manual
650 KB Download

Fluke RF-303

User manual
2.3 MB Download

Metron QA-ES

Service and user manual
600 KB Download

Fluke INCU

User manual
1.8 MB Download

Metron (Fluke) PS-320

Pin layouts for different connection cables
620 KB Download

Ohmeda Ohio Temperature Simulater for Incubators

Service and user manual
22.1 MB Download

Bio-Tek IDA-2

User manual
1.4 MB Download

Datrend Infutest 2000 E

User manual
820 KB Download

Metron QA-IDS

Service and user manual
390 KB Download

Hameg HM 604

User and service manual
4.7 MB Download

Hameg HM 604-2

User and service manual
6.8 MB Download

Hameg HM1005

User and service manual
3.6 MB Download

Rigol DS-1000

User manual
2.6 MB Download

Rigol DS-1000

Service manual
1.7 MB Download

Voltcraft 2040

Service manual
17.7 MB Download

BC Biomedical SPO-2000

User manual
210 KB Download

Datrend Oxitest Plus 7

User manual
740 KB Download

Metron SpO2

User manual
460 KB Download

Nellcor SRC-2

Technical manual
790 KB Download

Bio Tek 601 Pro

User manual
2.6 MB Download

Chauvin Arnoux Power Analyzer

User manual
1.1 MB Download

Chauvin Arnoux Netzanalyser

User manual
1.1 MB Download

Dale 600

Circuit diagram
800 KB Download

DNI Nevada 231D, 232D

User manual
3.7 MB Download

Dynatech Nevada 213, 215, 217

Service and user manual
1.1 MB Download

Dynatech Nevada 432D

Service and user manual
2.1 MB Download

Fluke 601 pro

User manual
4.7 MB Download

Fluke ESA-601

Getting started manual
730 KB Download

Metron QA-ST

Service and user manual
270 KB Download

Neuberger TG-0701

User manual
75 KB Download

Neuberger TG-0701

Specifications
115 KB Download

Neuberger TG-0701

Circuit diagram
125 KB Download

NSP-4000D

Quick user manual
2.0 MB Download

Janitza MRG-510

User manual
2.3 MB Download

Janitza MRG-510

Software description
610 KB Download

Metron QA-90

Service and user manual
1.0 MB Download

Rigel 233

User manual
250 KB Download

Rigel 266

User manual
280 KB Download

Center 309 Thermometer Data Logger

User manual
200 KB Download

Kal Equip 3000

Ebro EBI-10 Temperature Data Logger

User manual
5.5 MB Download

Fermitron Thermometer Tester

User manual
200 KB Download

Fluke 50S,50D Thermometer

User manual
80 KB Download

Fluke 51,52 Thermometer

User manual
170 KB Download

Fluke 53,54 Thermometer

User manual
20 KB Download

Fluke 65 IR-Thermometer

User manual
130 KB Download

Uni-t UT-320D Thermometer

User manual
1.8 MB Download

Hanna DIST-5

User manual
225 KB Download

Lutron CD-4303-HA

User manual
300 KB Download

AHP RT-200 Gas Flow Calibration Analyzer

User and service manual
1.6 MB Download

Allied RespiCal T300 Respiration Analyzer

User manual
5.7 MB Download

BC Biomed DPM-2001 - Pressure Meter

User manual
390 KB Download

BC Biomedical ULT-2000 Ultrasound Transducer Leakage Tester

User manual
900 KB Download

Bio-Tek UW-2 - Ultrasound Wattmeter

Kal Equipment 3000 Multimeter Manual Transfer Switch

User manual
1.4 MB Download

Bio-Tek VT-2 - Ventilator Tester

User manual
3.4 MB Download

Fluke VT Plus HF - Gas Flow Analyzer

User manual
12.1 MB Download

Greisinger GOX-100 - Oxygen Meter

User manual
170 KB Download

Gsponer MMD-1 Multi-MASmeter

User manual
400 kB Download

Ohio MiniOX 3000 Oxygen Monitor

User manual
1.0 MB Download

Ohio MiniOX 3000 Oxygen Monitor

Service manual
4.9 MB Download

RTI PMX-III X-Ray Multimeter

Service manual
2.3 MB Download

'Universal' LCD Multimeter M890G

Circuit diagram
530 KB Download

Fluke 175,177,179 Multimeter

Calibration procedure
2.2 MB Download

Fluke 175,177,179 Multimeter

User manual
1.0 MB Download

Hameg HM 5010-5011 Spectrum Analyzer

Service manual
5.0 MB Download

Hameg HM 8001 - Mainframe

User manual
980 KB Download

Hameg HM 8001 - Mainframe

Service manual
525 KB Download

Hameg HM 8011-2 - Multimeter

Service manual
3.4 MB Download

Kal Equipment 3000 Multimeter Manuals

Hameg HM 8011-3 - Multimeter

User manual
400 KB Download

Hameg HM 8012 Multimeter

Service manual
1.4 MB Download

Hameg HM 8021-3 - Universal Counter

User manual
315 KB Download

Hameg HM 3030-3 - Function Generator

Kal Equipment 3000 Multimeter Manual Pdf

User manual
3.3 MB Download

Hameg HM 3030-4 - Function Generator

User manual
5.2 MB Download

Hameg HM 7042-3 - Power Supply

User manual
280 KB Download

Hameg HM 8142 - Power Supply

User manual
1.4 MB Download

Manson NRP-2050 Power Supply

User manual
250 KB Download

Manson NRP-2050 Power Supply

Kal Equipment 3000 Multimeter Manual Tester

Service manual
5.5 MB Download

Peak Atlas DCA55 Component Tester

User manual
400 kB Download

Uni-t UT 61 Multimeter

User manual
4.5 MB Download

Kal Equip 3000 Digital Multimeter Manual

Uni-t UT 61E Multimeter

Circuit diagram
870 KB Download

Kal Equip 3000 Multimeter

Voltcraft M 3890 - Multimeter

User manual
770 KB Download

Version - 4.0

Digimet® 3000 Version 4.0

The Digimet 3000 Version 4.0 allows users to set limits for pulsator ratio parameters, like a high and low value for the B phase of pulsation.

When a user is collecting data with the Digimet 3000, the Digimet 3000 display will blink when a parameter value falls outside the desired limits.

This will give guidance to a user as to a potential problem with a pulsator and/or an indication of values that are not appropriate. Existing units are easily modified.

NEW FEATURE in the Digimet 3000 Version 4.0

The user will be able to set limits for the following Pulsator Ratio parameters:

  • Minimum and Maximum limits can be set for Maximum Vacuum per Pulse; A, B, C & D Phases; and Pulses per Minute.

  • A maximum limit can be set for B Fluctuation.

  • A minimum limit can be set for Minimum Vacuum per Pulse.

When viewing data in real time or viewing stored data, the values that are outside the set limits will blink on the Digimet display.

The Digimet 3000 is a 5-key, hand-held, battery operated, microprocessor- based vacuum and pulsation multi-function meter for measuring vacuum level characteristics and pulsation attributes in the dairy milking system. Use the Digimet 3000 for vacuum testing critical variables within the milking system. Useful in finding vacuum leaks, plugged lines, and pulsator phase monitoring. With the Digimet 3000, you can store data and recall it at a later time. The Digimet 3000's stored data can be either viewed on its LCD screen, uploaded to a computer or printed to the Digimet Printer. By monitoring vacuum levels, pulsator ratios, milk/rest ratios and pulsation electronics, the Digimet 3000 can evaluate system performance and improve milking efficiency.

Features:

  • 5-key membrane key pad.
  • 4-row by 16-character LCD.
  • Accepts pneumatic and electrical input.
  • User selectable shut-off from 0 to 30 minutes of non-use.
  • Battery life of approximately 40 hours.
  • Microprocessor based, menu-driven software.
  • Save five 10-second graphs with data collected at 125 Hertz.
  • Label data.
  • Check pulsator limping
  • NEW! Display blinks when Pulsator parameters are outside user set limits - (see explanation above).
  • Units measured may be inches of Hg or kPa.
  • Transfer stored data from the Digimet 3000 to a computer via a serial or USB connection (USB connection with user supplied USB to serial conversion cable).
  • Print stored data to the Digimet Printer.
  • The New Digimet 3000 Printer is supplied power by a wall transformer. The unit does not have an internal battery.
  • A Spanish language version of the Digimet is now available.
Testing that was developed by Western Dairies, Inc. Research & Development and Lionel H. Brazil, DVM, using the Digimet 3000, is referred to as the Digimet Accessories and that testing includes the following individual tests:

Our Fabric carrying case for the Digimet - DM3-FCASE

Our carrying case is made from black fabric material and is padded similar to a camera case. Its dimensions are 8 1/2 inches in length, 5 inches in width and 4 1/2 inches in depth. The front compartment has a nylon zipper and is for the Digimet unit. There is a second compartment on the back side which is also zippered and is for accessories. The carrying case is included with the Basic Digimet 3000.

Digimet® 3000Printer Top and Side views

The Digimet Printer unit consists of the printer and a voltage wall adapter. The printer can only be used by connecting the wall adapter power source (120 VAC). The paper roll and printer ribbon are stored within the printer enclosure.

Benefits - Digimet 3000

The NEW Digimet 3000 is the perfect tool to check vacuum levels and pulsation attributes in your dairy milking system. The Digimet 3000 is a timely answer to the demand for efficiency and cost-effectiveness in today’s dairy operation.

One can now spot-check critical variables within the milking system, save the data to a computer for historical review or print it out using the Digimet Printer for a quick printed record of the system's variables.

Let’s examine a couple of reasons why a dairy farmer or a dairy equipment dealer would want to use a tool like the Digimet 3000.

Reason #1: The vacuum gauge still reads the same near the receiver jar, but when two machines are being applied to the cows there seem to be more instances of squawking liners. Here’s a good use for your Digimet. Take a look at the vacuum at the teat end by plugging the Digimet's vacuum tube into the area around the claw. Maybe the vacuum has dropped below that vacuum level necessary to hold the teat cups on the teats.

Reason #2: You’re just not sure if all your pulsators are working properly. Well, it’s not going to be a quick or easy job, but once in a while you’ll just have to get the pulsator ratios of all your pulsators. Look at the ABCD phases of pulsation or take a look at a graph, print it out and analyze it. Save it in your computer until your dealer has time to take a look at it. There just is no other way to catch a failing pulsator. And the Digimet is perfect for this job.

Reason #3: With the NEW Digimet 3000 Version 4.0, your dealer or your equipment company can give you the proper parameter limits that your pulsators should operate at. Then input those parameter limits into the Digimet 3000 Version 4.0 and when reading real-time data from your pulsators or reading saved data stored in the Digimet 3000, the parameters that don't meet or exceed the limits set, will blink. This will make it easier to determine whether something is wrong or not.

Reason #4: Use the Digimet to check 'decay time' on automatic take-offs (ATO’s). For this purpose you will use the Store Graph feature in the Vacuum Level Function. Go to Store Graph, then choose a storage slot, label it or not, press the Menu key, then choose graph time of 10 seconds. At this point, Don’t press the Enter key until you are set up on the milking machine with the cow milking. Use a needle to plug into the short milk hose of one of the inflations and connect to the Digimet. While the cow is milking, put the ATO into manual. When the cow is milked out, press the Enter key on the Digimet immediately prior to pushing the removal button on the ATO. The Digimet will graph the next 10 seconds. When viewing the graph, at the point that the vacuum line drops vertically, this will indicate the vacuum level that remained in the teat cup at removal.

Reason #5: Let's say there is a discrepancy between the pneumatic pulsation ratio at the milking unit and what the perceived ratio should be. One item to check is the electronic output at the main pulsator box. Using the Digimet 3000, the banana clips provided and the Digimet electronic input ports, one can check the electronic output (12VDC to 24VDC) at the pulsator box to see if it matches the pneumatic ratio.

Reason #6: An item that is many times overlooked is whether or not the vacuum shut-off valve on the automatic take-off unit (ATO) is working properly. This test would be done while the vacuum system is on, but the milking unit is off and just hanging at the milking station. Configure a way to hook a needle or a 'T' up so that you can use the Digimet 3000 to check for the vacuum being leaked into the milk hose. For example, a needle inserted into a rubber cork that would fit into the end of the particular size of milk hose being used would suffice. Pull the milk hose off at the claw, plug the open end with the cork and then check for any vacuum with the Digimet 3000. If the shut-off valve is closing properly, no vacuum should be detected in the line. If the shut-off valve is leaking, a vacuum reading will appear on the Digimet's display screen. Use the Vacuum Level Function for this test.

Other uses for the Digimet 3000: In the Digimet version 3.4 and greater, one can check for Limping between the two sides of a pulsator. When storing pulsation data in the Dual mode, after collecting data on both sides of the pulsator, for example, 01A and 01B, the Digimet 3000 calculates the Limping Ratio for that pulsator. It indicates the difference in the A+B phases of the two sides of the pulsator, in percentage and in milliseconds.

The Digimet 3000 Complete consists of the Digimet 3000 Basic unit plus the Digimet Printer and a Large Hard Carrying Case, as shown below:

The newest version of the Digimet 3000 is version 4.0. This shows on the screen of the Digimet when you first turn the Digimet ON.

Two computer software programs accompany the Digimet 3000. One of them is a DOS program called Upload.exe and the other is a WINDOWS program, called digidata.exe.

Retrieve a two page data sheet on the Digimet 3000 Version 4.0. Click below or the Digimet 3000 Operator's Manual - 4C.