Coleman Powermate Owners Manual

Powermate Stationary Standby Electric Generator Owners Manual. Powermate - Coleman Electric Generator Operator's-Parts List Manual. Coleman Powermate PW0912400 Manuals: Coleman Pressure Washer Powermate PW0912400 Service manual (8 pages) 6: Coleman Powermate PW0912700 Manuals: Coleman Pressure Washer Powermate PW0912700 Service manual (8 pages) 7: Coleman Powermate PW0933501 Manuals: Coleman Pressure Washer Powermate PW0933501 Service manual (12 pages, 2.93 Mb) 8. Coleman Live Chat. We apologize if you are experiencing longer than usual call wait times or delayed responses to your questions through chat, email and social media. Some of our Coleman customer contact team members are working reduced office hours as a safety precaution due to the coronavirus affecting the regions where we operate.

  1. Coleman Powermate User Manual
  2. Coleman Powermate Owners Manual
  3. Coleman Powermate 6875 Owners Manual
  4. Coleman Powermate Generator Manual
CategoriesColeman Powermate Generator Manuals, Electric Generator Manuals
TagsColeman Powermate PMA525302
Download File
Document File TypePDF
CopyrightAttribution Non-commercial
(1 votes, average: 1 out of 1)
Home Appliance readers have rated Coleman Powermate PMA525302 Generator Owners Manual1.0 out of 1.0 based on 1 product reviews. Coleman Powermate Owners ManualColeman Powermate PMA525302 Generator Owners ManualSKUUPCModelRaul Rivera on

Coleman Powermate User Manual

May 01, 2018. ManagerColeman powermate generator manual

Coleman Powermate Owners Manual

good list.
We are looking to see more.

PMA525302.01 Insert Additif Adición ELECTRIC GENERATOR GROUPE ELECTROGENE GENERADOR ELECTRICO IMPORTANT ­ Please make certain that persons who are to use this equipment thoroughly read and understand these instructions and any additional instructions provided prior to operation. IMPORTANT – Prière de vous assurer que les personnes destinées à utiliser cet appareil ont pris soin d’en lire et d’en comprendre le mode d’emploi ou les directives avant de le mettre en marche. IMPORTANTE. Asegúrese que las personas que utilizarán este equipo lean y entiendan completamente estas instrucciones y cualquier instrucción adicional proporcionada antes del funcionamiento.

Power Equipment User Manual Free Download. Electric Generator for Power Manual. Free Manual Download PDF.

www.colemanpowermate.com 09/05 0063256 MAJOR GENERATOR FEATURES * * * * * 10 HP Tecumseh engine Cast-iron cylinder sleeve Low oil sensor Receptacles on control panel 5 gallon plastic fuel tank LIMITED WARRANTY Warranty Coverage: Powermate Corporation (the Company) warrants to the original retail customer in North America that it will repair or replace, free of charge, any parts found by the Company or its authorized service representative to be defective in material or workmanship. This warranty covers the cost of replacement parts and labor for defects in material or workmanship. Not Covered: · Transportation charges for sending the product to the Company or its authorized service representative for warranty service, or for shipping repaired or replacement products back to the customer; these charges must be borne by the customer. · Engine is covered exclusively by a separate warranty from the engine manufacturer, included with the engine Manual. · Damages caused by abuse or accident, and the effects of corrosion, erosion and normal wear and tear. · Warranty is voided if the customer fails to install, maintain and operate the product in accordance with the instructions and recommendations of the Company set forth in the owner’s manual, or if the product is used as rental equipment. · The Company will not pay for repairs or adjustments to the product, or for any costs or labor, performed without the Company’s prior authorization. Warranty Period: One (1) year from the date of purchase on products used solely for consumer applications; if a product is used for business or commercial applications, the warranty period will be limited to ninety (90) days from the date of purchase. For warranty service, the customer must provide dated proof of purchase and must notify the Company within the warranty period. For warranty service: Call toll free 800-445-1805, or write to Powermate Corporation, Product Services, 4970 Airport Road, P. O. Box 6001, Kearney, NE 68848. EXCLUSIONS AND LIMITATIONS: THE COMPANY MAKES NO OTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED. THE WARRANTY SERVICE DESCRIBED ABOVE IS THE EXCLUSIVE REMEDY UNDER THIS WARRANTY; LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL DAMAGES IS EXCLUDED TO THE EXTENT PERMITTED BY LAW. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow a disclaimer of implied warranties, or the exclusion or limitation of incidental and consequential damages, so the above disclaimers and exclusions may not apply to you. CONTROL PANEL A. 120 V, 20 Ampere Duplex Receptacle This duplex is split so that 20 amps of current may be drawn from each half of the receptacle. However, total power drawn must be kept within nameplate ratings.

Publisher: www.powermate.com

CategoriesColeman Powermate Generator Manuals, Electric Generator Manuals
TagsColeman Powermate PM0601100
Download File
Document File TypePDF
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

PM0601100 Insert Additif Adición ELECTRIC GENERATOR GROUPE ELECTROGENE GENERADOR ELECTRICO IMPORTANT ­ Please make certain that persons who are to use this equipment thoroughly read and understand these instructions and any additional instructions provided prior to operation. IMPORTANT – Prière de vous assurer que les personnes destinées à utiliser cet appareil ont pris soin d’en lire et d’en comprendre le mode d’emploi ou les directives avant de le mettre en marche. IMPORTANTE. Asegúrese que las personas que utilizarán este equipo lean y entiendan completamente estas instrucciones y cualquier instrucción adicional proporcionada antes del funcionamiento.

Power Equipment User Manual Free Download. Electric Generator for Power Manual. Free Manual Download PDF.

Coleman Powermate 6875 Owners Manual

Coleman Powermate, Inc. 4970 Airport Road P. O. Box 6001 Kearney, NE 68848 1-800-445-1805 1-308-237-2181 Fax 1-308-234-4187 www.colemanpowermate.com LFL 07/04 0062516 MAJOR GENERATOR FEATURES * * * * * * * * * 20 HP Honda OHV engine Cast-iron cylinder sleeve Low oil sensor Receptacles on control panel Electric Start Idle control CordKeeperTM 8 gallon plastic fuel tank Portability Kit E. CONTROL PANEL 120 Volt GFCI Receptacle Ground Fault Circuit Interrupter duplex receptacle is rated so that a total of 20 amps may be drawn regardless of whether both halves or just one receptacle is used. This receptacle may be used along with other receptacles provided the generator is not overloaded and total power drawn is kept within nameplate ratings. Ground Fault Circuit Interrupter (Conforms to U.L 943, Class A and NEC requirements) This device protects you against hazardous electrical shock that may be caused if your body becomes a path through which electricity travels to reach ground. This could happen when you touch an appliance or cord that is ” live ” through faulty mechanism, damp or worn insulation, etc. 120 Volt, 30 Ampere Twistlock Receptacle You may draw a maximum of 30 amps from this receptacle. If other receptacles are used at the same time, total power used must be kept within nameplate ratings. C. 120/240 Volt Heavy Duty Receptacle This receptacle is rated at 50 amps but the current must be limited to the nameplate rating. If this receptacle is used along with the 120 volt receptacles, the total load drawn must not exceed the nameplate ratings. Circuit Breakers The receptacles are protected by an AC circuit breaker. If the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE: Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker. D. B. A. Idle Control Switch The Idle Control circuit is designed to extend engine life and improve fuel usage by slowing the engine down to approximately 2000 RPM in a “No Load ” condition. The noise is also greatly reduced during this condition. When power is required from the generator an electronic control module automatically senses current flow in the electrical outlet and allows the engine to return to full speed or standard operating condition. Likewise, when the load is removed, the generator will automatically return to the idle condition after a 4-5 second delay.

Coleman Powermate Generator Manual

Publisher: www.powermate.com

Comments are closed.